Figure 2. circuit path, Table c. manual configuration guide, Table d. electronic provisioning settings – ADTRAN 2FXS/DPO PM User Manual
Page 3: Admin port remote port
3
Section 61109.403L2-5, Issue 3
61109.403L2-5C
Before provisioning the unit electronically, access the
channel unit by selecting:
Channel Unit Menus
(3)
Desired slot
(1-24)
Provisioning
(2)
Select current operational mode
(1-4)
Select desired provisioning option
(1-*)
For additional information on EASYMENU
operation or
the ADTRAN Site Manager, refer to the EASYMENU
User Manual, document number 61150.055L1-1 (found
in the ACT 2300/1900 System Manual, document number
2150.050-3), or the Site Manager User Manual, document
number 64150.075L1-1. For additional information about
the LIU-3/PM see the LIU-3/PM User Manual, part
number 61151.001L2-1.
Initial Turn-up
Refer to the desired operational mode in Table C for the
correct provisioning options.
Transmit Attenuation
Determine the input TLP. Then use the following formula
to calculate the amount of transmit attenuation to add to
the circuit:
Tx Attenuation=Input TLP + Internal Tx TLP of 4.5
dBm
For example, if an input TLP level of -3 dB is to produce
a level of 0dBm0 at TLP0, then the Transmit Attenuation
should be set to 1.5 dB.
Receive Attenuation
Determine the output TLP. Then use the following
formula to calculate the amount of receive attenuation to
add to the circuit:
Rx Attenuation=Internal Rx TLP of 0 dBm) - Output
TLP
For example, if 0dBm0 at TLP0 is required to produce an
Output TLP level of -3 dB, then the Receive Attenuation
should be set to 3 dB. Figure 2 provides an illustration
of attenuation settings.
Figure 2. Circuit Path
The trunk processing options are provisioned
only by switch SW7. Electronic provisioning is
not available.
Table C provides a guide to ensure proper provisioning
of the desired channel unit mode.
Table C. Manual Configuration Guide
Electronic Provisioning
ADTRAN EASYMENU
is used to electronically provision
the unit. Connect a VT 100 terminal or a computer
running a terminal emulation program to the faceplate
ADMIN port or REMOTE port using a standard male-to-
male RS-232 cable. The settings for the ADMIN and
REMOTE ports are shown in Table D.
A null modem cable is required to connect the
REMOTE port directly to a terminal.
Table D. Electronic Provisioning Settings
Once connected, enter the password. The factory default
password is PASSWORD in all capital letters. The
password may be changed by selecting:
Common Module Menus
(2)
BCU
(1)
Configuration
(1)
Read/Write Password
(9)
X
FXS
Loop
Start
X
X
X
X
Off
On/Off
On/Off
Off
Off
On
Off
X
FXS
Gnd
Start
X
X
X
X
On
On/Off
On/Off
Off
Off
On
Off
RTG
(SW4-1)
Options
DTG
(SW4-2)
TWS
(SW4-3)
TRB
(SW4-4)
PD3
(SW4-5)
GS
(SW4-6)
DPC
(SW4-7)
SD
(SW4-8)
TNDM
(SW3-2)
PLAR
(SW3-3)
FXS
(SW3-4)
DPO
(SW3-5)
On/Off
On/Off
On/Off
On/Off
X
Off
X
On/Off
On
Off
Off
TANDEM
Loop
Start
Off
TANDEM
Gnd
Start
On/Off
On/Off
On/Off
On/Off
X
On
X
On/Off
On
Off
Off
Off
PLAR
On
X
X
X
On/Off
X
X
On/Off
Off
On
Off
Off
DPO
X
X
X
X
X
X
X
On/Off
Off
Off
Off
On
Note: X = Switch position is ignored.
ADMIN Port
REMOTE Port
Settings
9600 baud
SW2 baud
No Parity
No Parity
8 bits
8 bits
1 stop bit
1 stop bit
0- 6.3 dB
TLPO
Tx Atten
T
R
TDATA
0 dBm0
0- 6.3 dB
-4.5 to +1.8 dB
0 to -6.3 dB
TLPO
Rx Atten
RNPCM
0 dBm0
Transmit Path
Receive Path
Input TLP
Output TLP