QT

SECTION XI

BURNER/TUMBLER HI-LIMIT MANUAL

RESET INSTRUCTIONS

Both the top and bottom tumbler of this dryer is equipped/manufactured with a burner manual reset hi-limit and
manual reset tumbler/lint chamber hi-limit thermostat. If either manual reset hi-limit thermostat is open prior to
the start of the drying cycle, or during the drying cycle, the dryer will not recognize the open (tripped) state of
the applicable basket/tumbler hi-limit thermostat and will start or continue through the drying cycle with no
heat. The applicable open/tripped manual reset hi-limit must be reset manually. This hi-temperature condition
may be caused due to a restricted exhaust, poor airflow, or improper burner operation. The burner manual reset
hi-limit is located at the gas/valve manifold left burner chamber area. The tumbler manual reset hi-limit is
located in the (right) lint chamber area.

IMPORTANT

This dryer is equipped with a burner

hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.

WARNING: Discontinue power to dryer

before attempting to reset hi-limit.

ADC P/N:114093