Providing local codes permit, power to the dryer can be made by use of a flexible U.L. listed power
cord/pigtail (wire size must conform to the rating of the dryer), or the dryer can be hard wired directly
to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the
dryer.

4. 3-Phase (3ø) Wiring Connections

The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes
Neutral) and ground. Single phase (1ø) power for the control circuit and for any single-phase (1ø) motors
(if present) is done internally to the dryer. No single-phase (1ø) input connection is required on a
3-phase (3ø) dryer.

a. 3-Phase (3ø) Hookup

For gas dryers manufactured for operation at 3-phase (3ø), the electrical connections are made at the
power distribution block located in the service box at the rear, upper left hand corner of the dryer. To
gain access to the service box and contactor, the service box cover must be removed.

Providing local codes permit, power to the dryer can
be made by use of a flexible U.L. listed power cord/
pigtail (wire size must conform to the rating of the
dryer), or the dryer can be hard wired directly to the
service breaker panel. In both cases, a strain relief
must be installed where the wiring enters the dryer.

S

INGLE

-P

HASE

(1

Ø

)

E

LECTRICAL

C

ONNECTIONS

L

EADS

Black

+

Positive

White

-

Neutral

Green

Ground

or

L2