American Dryer Corp. AD-235ED User Manual

Page 24

background image

OM

ADG-230D (Gas)

ADG-235ED (Gas)

E

LECTRICAL

S

ERVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT: 208 VAC

AND

230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE:

A. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size

according to appliance amp draw rating and type of breaker used.

B. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

(60 Hz)

MINIMUM

WIRE SIZE*

CIRCUIT

BREAKER

120

2

9.6

14

20

208

2

5.8

14

15

230/240

2

5.3

14

15

208

3

2.9

14

15

230/240

3

3.2

14

15

* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48m).

NOTE: Contact factory for electrical information not listed.

NOTE: ADC reserves the right to make changes in specifications at any time without notice

or obligation.