American Dryer Corp. AD-235ED User Manual
Page 24

OM
ADG-230D (Gas)
ADG-235ED (Gas)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC
AND
230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE:
A. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
B. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
(60 Hz)
MINIMUM
WIRE SIZE*
CIRCUIT
BREAKER
120
1ш
2
9.6
14
20
208
1ш
2
5.8
14
15
230/240
1ш
2
5.3
14
15
208
3ш
3
2.9
14
15
230/240
3ш
3
3.2
14
15
* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48m).
NOTE: Contact factory for electrical information not listed.
NOTE: ADC reserves the right to make changes in specifications at any time without notice