beautypg.com

Ype of – American Dryer Corp. AD-235ED User Manual

Page 26

background image

OO

2. Technical Gas Data

a. Gas Specifications

b. Gas Connections:

Inlet connection -------------- 3/4-inch N.P.T.
Inlet supply size ------------- 3/4-inch N.P.T. (minimum)
Btu/hr input (per dryer) ----- 144,000 (36,288 kcal/hr)
Btu/hr input (per pocket) --- 72,000 (18,144 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
water column (W.C.) - 29.9 mb - pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches water column (26.1 mb.) There is no regulator
or regulation provided in a L.P. dryer. The water column pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.

T

YPE OF

G

AS

Natural

Liquid Propane

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are stated in metric equivalents

* Measured at gas valve pressure tap when the gas valve in on.

T

YPE OF

G

AS

Liquid Propane

(L.P.)

Conversion Kit

Part Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating **

Natural

Liquid Propane (L.P.)

Qty.** D.M.S.*

Part

Number

Qty.** D.M.S.*

Part

Number

ADG-230D

ADG-235ED

72,000

18,144

1

#20

140828

1

#41

140811

874059

Shaded area is stated in metric equivalent

* D.M.S. (Drill Material Size) equivalents are as follows:
** Each pocket/tumbler

Natural Gas ............... #20

= .1610" (4.089 mm)

Liquid Propane Gas .. #41

= .0960" (2.438 mm)

This manual is related to the following products: