2.3.2 Table of adjustments and flow rates
 
 
Gas type 
G20 (1)
G25 (2)
G31 G31
Pres. 
feed.(mbar) 
20 20 37 50
Injector 
marking 
180 200 120 110
Adjustment of 
air pres. 
Max opening of 
vent 
Idem Idem Idem
Flow of burner 2.64(cubic m/h) 3.07(cubic m/h) 1.96 (kg / h)
1.96 (kg / h)
Nominal heat 
flow kW (hi) 
24.9
24.9
24.9
24.9 
 
 
 
(1)
Identical adjustment for G25 at 25 mbar
(2)
Germany only
 
* G20: natural gas type H (Lacq) 
* G25: natural gas type L (Groningen) 