SPEC TableEPS
SPEC Table
NRP-HC1001
Model
NRP-HC1001
SPECIFICATION
Power
1000W
Dimension
200mm(L)x150mm(W)x86mm(H)
Switches
ATX Logic on-off additional power rocker switch
PFC
Active PFC (PF > 0.9)
Cooling System
140mm Fan, 2300RPM±10%
Noise
16 dBA at 1300RPM
P.G. Signal
100-500 ms
Efficiency
Up to 87%
Hold-up Time
16 ms
INPUT
Input Voltage
100-240VAC
Input Frequency Range
50/60Hz
MTBF
120,000 hrs minimum (at 25℃)
Input Current
13A
Output
Max/Min
Regulation *1 Ripple & Noise *2
Output
+12V1
20A/1A
+3, -3%
120mV
500W
+12V4
36A/1A
+3, -3%
120mV
+3.3V
30A/0.5A
+3, -3%
50mV
+12V2
20A/1A
+3, -3%
120mV
500W
+12V3
36A/1A
+3, -3%
120mV
+5V
30A/0.5A
+3, -3%
50mV
-12V
0.8A/0A
+10, -10%
120mV
9.6W
+5Vsb
3.5A/0A
+3%, -5%
50mV
17.5W
Total Power
1000W
Peak Power
1100W
1. +5Vsb operate at 3.5A max load base on PS-ON mode. If PS-OFF +5Vsb only operate at 3A max load.
2. Add 0.1μF capacitors across output terminal during ripple & noise test.
Environment
Operating Temp.
10℃ to 50℃
Storage Temp.
-20℃ to 70℃
Operating Humidity
20% to 90%, non-condensing
Storage Humidity
5% to 95%, non-condensing
Protection
DC Rail
Trigger Point/Range
Over Voltage Protection
+3.3V trip point
4.5 Vmax
+5.0V trip point
7.0 Vmax
+12.0V trip point
15.6 Vmax
Over Current Protection
+3.3V
33A ~ 50A
+5.0V
33A ~ 50A
+12V1 & +12V2
22A ~ 35A
+12V3 & +12V4
39A ~ 55A
Under Voltage Protection
+3.3V trip point
2.0 Vmin
+5.0V trip point
3.3 Vmin
+12.0V trip point
8.5 Vmin
Short Protection
All output to GND
10
H