PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Ammeter reading

stays high.

Battery is severely discharged.

Wrong battery voltage.

Continue charging battery for two

more hours. If problem continues

have the battery checked.

Verify the voltage settings on the

charger are correct.

Ammeter reads less

than selected charge

rate when charging

a discharged battery.

Extension cord is too long or

wire gauge is too small.

Weak cell or sulfated plate in

battery.

Battery is only partially

discharged.

Use a shorter or heavier gauge

extension cord.

A sulfated battery will eventually

take a normal charge if left

connected. If the battery will not

take a charge, have it checked.

Continue to charge the battery.

The charger is

making an audible

clicking sound.

Circuit breaker is cycling.

Battery is defective.

Shorted battery cables or clips.

Severely discharged battery, but

otherwise it is a good battery.

Reverse connections at battery.

The settings may be wrong. Check

the charger settings.

Have the battery checked.

Circuit breaker cycles when current

draw is too high. Check for shorted

cables or clips and replace if

necessary.

The battery may not want to accept

a charge due to a run-down state.

Allow charging to continue until

battery has a chance to recover

sufficiently to take a charge. If more

than 20 minutes, stop charging and

have the battery checked.

Shut the charger off and correct the

lead connections.

Charger makes a

loud buzz or hum.

Transformer laminations vibrate

(buzz).

Shorted Diode Assembly or

Output Rectifier Assembly (hum).

No problem, this is a normal

condition.

Have charger checked by a

qualified technician.