Distinctive ring send_commands – AMX DTMF+ Interface AXB-DTMF+ User Manual
Page 21

Programming
17
AXB-DTMF+ DTMF+ Interface
Distinctive Ring Send_Commands
The following Send_Commands are available for changing the default distinctive ring patterns.
Each ring pattern consists of five parts with each part requiring a Send_Command.
Distinctive ring Send_Commands produce four patterns (P1 through P5) and high and low time
values (_X). Refer to FIG. 1 on page 15 to see the timing diagram based on defaults at start-up/
reset.
Distinctive Ring Send_Commands
Command
Description
P1_1-XXX
Pattern 1 Part 1 high time for distinctive ring.
• Time increment = 10 ms
• Default at reset = 200
Example:
SEND_COMMAND DTMF, 'P1_1-300'
Sets the distinctive ring Pattern 1 Part 1 high time for 3.0 seconds (3000 ms).
P1_1-XXX
Pattern 1 Part 1 high time for distinctive ring.
• Time increment = 10 ms
• Default at reset = 200
Example:
SEND_COMMAND DTMF, 'P1_1-300'
Sets the distinctive ring Pattern 1 Part 1 high time for 3.0 seconds (3000 ms).
P1_2-XXX
Pattern 1 Part 2 low time for distinctive ring.
• Time increment = 10 ms
• Default at reset = 0
Example:
SEND_COMMAND DTMF, 'P1_2-05'
Sets the Pattern 1 Part 2 low time for .05 seconds (50 ms).
P1_3-XXX
Pattern 1 Part 3 high time for distinctive ring.
• X=(Time increment) = 10 ms
• Default at reset = 0
Example:
SEND_COMMAND DTMF, 'P1_3-05'
Sets the Pattern 1 Part 3 high time for .05 seconds (50 ms).
P1_4-XXX
Pattern 1 Part 4 low time for distinctive ring.
• Time increment = 10 ms
• Default at reset = 0
Example:
SEND_COMMAND DTMF, 'P1_4-05'
Sets the Pattern 1 Part 4 low time for .05 seconds (50 ms).
P1_5-XXX
Pattern 1 Part 5 high time for distinctive ring.
• Time increment = 10 ms
• Default at reset = 0
Example:
SEND_COMMAND DTMF, 'P1_5-05'
Sets the Pattern 1 Part 5 high time for .05 seconds (50 ms).