Programming
12
AXB-DTMF+ DTMF+ Interface
Timing System Send_Commands (Cont.)
Command
Description
OREOFFMAX-XXX
Outgoing reorder (fast busy) off time maximum.
• Time increment = 10 ms
• Default at reset = 35
Example:
SEND_COMMAND DTMF, 'OREOFFMAX-45'
Sets the outgoing reorder (fast busy) off time maximum to .45 second (450 ms)
(see NOTE for Send_Command 'OBUOFFMAX-XXX ').
For the code to work properly, ring, busy, and reorder time values must be set
so that ring is greater than busy, and busy greater than reorder
(ring>busy>reorder).
OREOFFMIN-XXX
Outgoing reorder (fast busy) off time minimum.
• Time increment = 10 ms
• Default at reset = 15
Example:
SEND_COMMAND DTMF, 'OREOFFMIN-20'
Sets the outgoing reorder (fast busy) off time minimum to .20 second (200 ms)
(see NOTE for Send_Command 'OBUOFFMAX-XXX ').
For the code to work properly, ring, busy, and reorder time values must be set
so that ring is greater than busy, and busy greater than reorder
(ring>busy>reorder).
OREONMIN-XXX
Outgoing reorder (fast busy) on time minimum.
• Time increment = 10 ms
• Default at reset = 15
Example:
SEND_COMMAND DTMF, 'OREONMIN-20'
Sets the outgoing reorder (fast busy) on time minimum to .20 second (200 ms)
(see NOTE for Send_Command 'OBUOFFMAX-XXX ').
For the code to work properly, ring, busy, and reorder time values must be set
so that ring is greater than busy, and busy greater than reorder
(ring>busy>reorder).
ORIOFFMAX-XXX
Outgoing ring off time maximum.
• Time increment = 100 ms
• Default at reset = 44
Example:
SEND_COMMAND DTMF, 'ORIOFFMAX-50'
Sets the outgoing ring off time maximum to 5.0 seconds (5,000 ms) (see NOTE
for Send_Command 'OBUOFFMAX-XXX ').
ORIOFFMIN-XXX
Outgoing ring off time minimum.
• Time increment = 100 ms
• Default at reset = 26
Example:
SEND_COMMAND DTMF, 'ORIOFFMIN-40'
Sets the outgoing ring off time minimum to 4.0 seconds (4,000 ms) (see NOTE
for Send_Command 'OBUOFFMAX-XXX').