beautypg.com

Innovate Motorsports LM-1 Digital Air/Fuel Ratio (Lambda) Meter User Manual

Page 23

background image

- 23 -

Appendix B: LM-1 Error Codes and Troubleshooting Tips

Error
Code

Error Message

Likely Root Cause

Fix

Error 1

Heater circuit shorted

1. Short in cable
2. Short in sensor

1. Repair/replace

cable.

2. Replace

sensor.

Error 2

Heater circuit open

1. Damaged cable or DIN

connector not fully seated

1. Verify DIN connector is fully

seated into unit. Repair/replace
cable.

Error 3

Pump cell circuit shorted

1. Short in cable
2. Short in sensor
3. Sensor heater calibration

incorrect

4. Sensor

overheating

5. EGT >1700º F

1. Repair/replace

cable.

2. Replace

sensor.

3. Perform sensor heater

recalibration.

4. Move your sensor bung as

far downstream as possible
OR add a heatsink to isolate
the sensor from the pipe.

5. “”

Error 4

Pump cell circuit open

1. Damaged cable or DIN

connector not fully seated

2. Sensor heater calibration

incorrect

1. Verify DIN connector is fully

seated into unit. Repair/replace
cable.

2. Perform complete heater

calibration (not just free air
calibration). See section 4.6

Error 5

Reference cell circuit
shorted

1. Short in cable
2. Short in sensor

1. Repair/replace

cable.

2. Replace

sensor.

Error 6

Reference cell circuit open

1. Damaged cable or DIN

connector not fully seated

2. Damaged

Sensor

1. Verify DIN connector is fully

seated into unit. Repair/replace
cable.

2. Replace

sensor

Error 7

General System error
(typically a software error).

Typically a software error

Reboot LM-1. Re-flash unit if

necessary.

Error 8

Sensor Timing error
(typically a damaged
sensor).

1. Sensor overheating.

(The Bosch LSU4.2 is rated
to operate at a sensor
housing temperature of < 900
degrees (measured at the
bung) for maximum accuracy
and control. When this
operating temperature range
is exceeded, the sensor can
no longer be accurately
controlled. )

2. Sensor is damaged

1. a. Perform sensor heater

recalibration; b. Move your
sensor bung as far
downstream as possible. Right
before the cat, or 2-3 feet from
the end of the tailpipe are good
locations; c. Add a heatsink to
isolate the sensor from the
pipe. The HBX-1 is an
available accessory.

2. Replace

sensor.

Error 9

Supply Voltage too low

Supply voltage too low for
sensor regulation

Bypass cigarette-adapter,
recharge battery, or improve
electrical system