COUNTERBALANCE VALVE

PURPOSE of the counterbalance valve is to prevent the front gate from closing before the

rear pushgate is fully retracted when the scraper is empty. This enables the operator to

start the next cut without having to reopen the gate from the closed position.

INSTRUCTIONS for establishing counterbalance valve setting:

When properly adjusted, the front gate will close 40% from full open position (26 ½”

from bottom of gate to cutting edge) and hold at that position until the rear pushgate is

fully retracted. If the front gate is closing more than 40%, loosen the lock nut under the

hex socket head screw and turn the screw clockwise until the front gate holds at that

position. Turn an additional ¼ turn clockwise, then tighten the lock nut. DO NOT turn

the adjusting screw more than is necessary to hold the front gate at 40% open.

20