MTX-986C-SL STATUS INDICATORS

The MTX-986C-SL transmitter provides the following front panel LED status indicators to aid in
installation and troubleshooting:

af i

american fibertek

DATA RX/TX INDICATORS

DATA RX and DATA TX indicators are provided to monitor each of the two available data
channels. DATA 1 RX and TX correspond with the multi-protocol output/input of DATA CH 1.
DATA 2 RX and TX correspond with the status of the Contact (open/closed).


DATA RX/CONTACT STATUS

A green LED indicator is provided to monitor the data coming in from the fiber, through the
MTX-986C-SL, and out onto the electrical interface. The intensity of this indicator will vary with
input data patterns, however in typical applications it will cycle on and off as data is received.
Data received status associated with this LED is summarized below.

DATA RX LED

Data 1 Status

Data 2 (Contact) Status

Green

Data Flow Present

Contact Closed

Off

Data Flow Not Detected

Contact Open


DATA TX/CONTACT STATUS

A green LED indicator is provided to monitor the data coming in from the electrical interface,
through the MTX-986C-SL, and out onto the fiber. The intensity of this indicator will vary with
input data patterns, however in typical applications it will cycle on and off as data is transmitted.
Data transmitted status associated with this LED is summarized below.

DATA TX LED

Data 1 Status

Data 2 (Contact) Status

Green

Data Flow Present

Contact Closed

Off

Data Flow Not Detected

Contact Open


VLI 1 THROUGH VLI 8

A bi-color LED indicator is provided for the each of the eight video inputs to the MTX-986C-SL.
Video status associated with each of these LED’s is summarized below.

Video Presence LED

Video Status

Green

Proper Input Video Present

Red

Input Video Not Detected


OLI

A bi-color LED indicator monitors the optical input power of the data signal that is being
received at the MTX-986C-SL from the MRX-986C-SL. AC power and optical input status
associated with this LED are summarized below.

Optical Level Indicator

AC Power Status

Optical Status

Green

On

Proper Optical Input Power Present

Red

On

Optical Input Not Detected

Off

Off

Check Power Supply Input