beautypg.com

Inst – Anetsberger Brothers SLG40 User Manual

Page 6

background image

6

WARNING

Fryers MUST have a movement-
limiting (restraining cable) device
installed to prevent tipping that
causes splashing or spilling its HOT
contents.

NOTE: This movement-limiting de-
vice is to be furnished and in-
stalled
by the fryer’s installing
contractor before
the fryer is con-
nected to the gas line at its desired
location.

1. Install one restraining device connector

securely into the structure wall directly behind
the fryer’s desired location (Figure 2).

2. Install one restraining device connector on the

rear panel of the fryer very close to the quick-
disconnect device on the end of the fryer’s gas
line.

3. Attach one end of the restraining cable to the

wall connector. Attach the other end to the
fryer connector.

4. Confirm that the fryer cannot move far enough

away from the wall to cause excessive move-
ment of the flexible gas line or its associated
connectors.

FRYER RESTRAINING DEVICE INSTALLATION INSTRUCTIONS

!

Install the fryer in accordance with the preceding
Code Requirements, as well as the following
Installation Requirements.

1. DO NOT install this fryer in a mobile home,

trailer, or recreational vehicle.

2. Install this fryer in a location that allows it to be

moved away from other adjacent appliances
for cleaning and maintenance.

NOTE: If the fryer is installed among
a row of appliances (“banked”), with
its only convenient movement forward,
sufficient room must be available in
front of the fryer to permit its separa-
tion from adjacent appliances for
cleaning and maintenance.

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION REQ

TION REQ

TION REQ

TION REQ

TION REQUIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

3. Tightly fasten the legs (or casters) to the bot-

tom of the fryer using the supplied hardware, to
prevent the fryer from tipping, wobbling or
rocking when it is in its desired location. Refer
to the following Leg Installation Instructions
or Caster Installation Instructions for leg
or caster attachment and leveling information.

!

CA

CA

CA

CA

CAUTION:

UTION:

UTION:

UTION:

UTION: Hood make-up air

MUST NOT flow in a manner that
restricts or impedes the natural flow
of combustion or ventilation air.

4. Confirm that the air from the ventilation hood

flowing near the fryer after installation is NOT
blowing on the rear of the unit, to prevent
affecting the burner flames and possibly causing
control damage.