FRYER GAS SUPPLY SPECIFICATIONS

Please make sure that your desired fryer location has gas

supply factors that are suitable for this product:

Gas Supply Inlet Pipe must be ½“ standard gas
line. The gas supply inlet line should be as straight
as possible (fewest bends or elbows) to obtain the
highest available gas pressure at the fryer. Locate
this inlet line horizontally at the center of the
desired fryer location, approximately 8¼“ above
the floor.

1. Carefully examine the shipping carton for

external damage. When damage is noted, notify
the delivery carrier immediately. Save all packing
materials for damage claim examination.

2. If no external damage is noted, remove the

shipping carton from the fryer and examine the

SHIPPING CONT

SHIPPING CONT

SHIPPING CONT

SHIPPING CONT

SHIPPING CONTAINER INSPECTION

AINER INSPECTION

AINER INSPECTION

AINER INSPECTION

AINER INSPECTION

* -

Rating is based on sea level operation. Reduce rating 4% for each 1000 feet above sea level.

** -

W.C. = Inches, Water Column.

*** -

Measure Supply Pressure when all other gas-powered equipment is operating.

fryer carefully for damage. Place the fryer in a
safe location, if damage is noted, so that the freight
damage claims adjuster can examine the fryer.

3. Save the shipping container for use during leg/

caster installation. Refer to the Installation Instruc-
tions for that procedure.

Standard Accessories furnished in the shipping
carton for this fryer include:

2 Fryer Baskets

1 Screen

4 Adjustable Legs

1 Drain Valve Extension

1 Basket Hanger

1 Flue Deflector

SUPPLY PRESSURE

***

Natural Gas

Propane

3½“ W.C.

**

10“ W.C.

6“ W.C., minimum

11“ W.C., minimum

INPUT REQUIRED:

90,000 BTU/Hr

*

MANIFOLD PRESSURE

NOTE: Using a flexible inlet line permits varia-
tion in the gas supply line location, both horizontally
and vertically.

Anets fryers are only for use with the type of gas
specified on the spec plate. If a fryer requires
modification to use a gas other than that which is
identified on the fryer spec plate, contact your
Anets representative or call (800) 837-2638.

Optional Accessories available for this fryer
include:

Single or Triple Fryer Baskets
1 Set (4) of Casters

Model Covered By This Manual

Model

Features

SLG40

Stainless Steel Fryer Kettle