STEINEL HFLUM2-WR User Manual
Page 8

8
No power at the
sensor
Lights do not switch
ON
Lights do not switch
OFF
Lights switch ON
without obvious
movement
breaker has tripped; light switch is in
OFF position
short circuit
light level setting is in nighttime
mode during daytime operation
lamp burned out
power is off
detection zone not correctly adjusted
sensor is detecting movement
outside of desired coverage area
sensor is detecting movement
outside of desired coverage area
reset breaker, turn light switch
to ON position, check wiring
with voltage tester
check for proper wiring
connections
adjust light level setting
replace lamp
turn power on at circuit breaker
readjust
reduce sensitivity
reduce sensitivity
Troubleshooting
Warranty
STEINEL America warrants its products
against defects in material or workmanship
for a period of
five years. STEINEL will
replace or repair the item provided that it
has not been altered or subjected to abuse,
accident, improper installation or improper
use. There are no obligations or liabilities
Contains:
FCC ID - W8J-SIR13
IC - 8529A-SIR13
NOTICE:
This device complies with Part 15 of the
FCC Rules and with RSS-210 of Industry
Canada. Operation is subject to the
following two conditions:
(1) this device may not cause harmful
interference, and
M-15104-1
www.steinel.net
(800) 852-4343
on the part of STEINEL for consequential
damages arising out of or in connection with
the use or performance of this product or
other indirect damages with respect to loss
of property, revenue, or profit, or cost of
removal, installation or reinstallation.
(2) this device must accept any
interference received, including
interference that may cause undesired
operation.
NOTICE:
Changes or modifications made to the
equipment not expressly approved by
Steinel GmbH may void the FCC / IC
authorization to operate this equipment.
Malfunction
Cause
Remedy