Important: The wire connectors included with this receptacle

are intended to only be used with copper wire. Consult a

qualified electrician if you have aluminum wiring.
Instructions:

Strip insulation 3/8” for 12 or 14 AWG wire. Strip insulation

7/16” for 16 or 18 AWG wire.
Hold stripped ends together in parallel and align any frayed

strands (do not twist wires).
Push wires firmly into connector. Twist connector clockwise

with fingers until tight. Pull wires to check for tightness.

Wire Connector / Combination Chart

One #14 w/one-to-four #16 or #18

One #12 w/one-to-three #14 or #16 or #18

Two #14 w/one-to-three #16 or #18

Two #12 w/one or two #14 or #16 or #18

You should now be able to use the front panel pushbutton

to manually turn On/Off a lamp plugged into the Z-Wave

controlled outlet.

Use your primary controller to include the receptacle in the

home control network after the receptacle is installed as

shown in the above diagram. It can then be added to groups

and/or lighting scenes and managed remotely to control the

ON/OFF status of the connected lighting.