Design information, Warning, Product dimensions and clearances – GE ZGP304NRSS User Manual
Page 6: 30” wide range models

6
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
30” Wide Range Models
13”
Max.
3-1/4”
to 4-3/4”
1-1/2”
35-1/4”
to
36-3/4”
Height
30” Min.
28-1/4”
30”
4-5/8”
11-3/8”
2”
7-3/8”
Gas/
Electric
Gas/
Electric
6-1/2”
2”
WARNING
Installations without a hood require
48” minimum to combustibles.
A custom hood installation with
exposed horizontal combustible
surfaces must have an Auto-On
feature. Refer to hood installation
instructions for specific hood
clearances.
The surface of the entire back wall
above the range and below the
hood must be covered with a non-
combustible material such as metal,
ceramic tile, brick, marble or other
stone.
Universal Utility Locations
Non-
Combustible
Material
12”
Minimum
Each Side
12” Minimum
to Adjacent Wall
48” Minimum
to
Combustibles
Depth
to Front
of Door
Toekick/
leg Height
29-7/8” Width
Countertop
to Cooking
Surface
18”
Min.
NOTE: All openings in the floor
or wall behind and below the
appliance shall be sealed.
ADDITIONAL CLEARANCES:
Allow 12” minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18” minimum clearance between countertop and
the bottom of the wall cabinet.
For island installation, maintain 2-1/2 in. minimum from
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
Back
3” Min.
Island
Cutout
Top View
3” Min.
2-1/2” Min.