Installing a pci express riser board – HP ProLiant DL360 G4p Server User Manual
Page 60

60
HP ProLiant DL360 Generation 4p Server User Guide
8. Install the expansion board into the slot until it seats firmly.
IMPORTANT: If the expansion board ships with an extender bracket,
remove it from the expansion board before inserting the board into the
expansion slot of the PCI riser board assembly.
IMPORTANT: Be sure that all DIMM slot latches are closed to provide
adequate clearance before installing the PCI riser board assembly with
a half-length expansion board.
9. Install the PCI riser board assembly.
IMPORTANT: The server will not power up if the PCI riser board
assembly is not seated properly.
NOTE: The same procedures apply for installing an expansion board in
PCI expansion slot 1.
Installing a PCI Express Riser Board
1. Power down the server ("Powering Down the Server" on page
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page
3. Remove the access panel ("Removing the Access Panel" on page
4. Remove the PCI riser board assembly.
5. Remove the expansion slot cover from the slot, if installed ("Installing an
Expansion Board" on page