Patch Release Note

Patch 86222-10 for Software Release 2.2.2

C613-10319-00 REV J

The Trigger Facility was generating a trap with variable { 0 0 }, and was not
documented in the ATI enterprise MIB. This issue has been resolved. The
MIB object triggerLastTriggerActivated ({ enterprises(1) alliedTelesyn(207)
mibObjects(8) brouterMib(4) atrouter(4) modules(4) trigger(53) 1 }) has been
defined, to record the trigger number of the last trigger activated, and this
variable is now transmitted in the trigger activation trap triggerTrap.

In a Rapier G6, fitted with a fibre uplink module with all ports active,
switching traffic between port 1 and the uplink caused the traffic flow to
cease after a period of time depending on the volume of traffic. This issue
has been resolved.

The Rapier did not include the message age of the received BDPU message
in the message age of the BDPU it transmitted. Also, the message age of the
message transmitted BDPU could be less than that of the received BDPU,
which contravenes IEEE 802.3d. This issue has been resolved.

Reception of incorrectly tagged packets was causing corruption of the ARL
table, eventually causing the switch to lock up. This issue has been resolved.
Tagged packets with invalid VLAN identifiers are now discarded. The
INFILTERING parameter of the SET SWITCH PORT command now
defaults to ON.

Flow control performance has been improved.

The IPsec SA ID now wraps correctly at the 16 bit (ID = 65535) boundary.
The ID is also checked to verify that it is free before it is used.

If PPPoE AC services were not deleted in the same order they were added,
the DELETE command would return an “ operation successful” message
but the service would still appear in the output of the SHOW PPP PPPOE
command. This issued has been resolved.

The CREATE CONFIG command did not include all required L3FILTER
parameters in the generated script file.

The L3 table on the Rapier G6 is now cleared when a switch port goes down
to ensure the L3 and ARP tables are consistent.

PCR: 01213

Module: TRG, SNMP

Network affecting: No

PCR: 01214

Module: SWI

Network affecting: No

PCR: 01216

Module: STP

Network affecting: No

PCR: 01219

Module: VLAN,SWI

Network affecting: No

PCR: 01221

Module: SWI

Network affecting: No

PCR: 01225

Module: IPSEC

Network affecting: No

PCR: 01227

Module: PPP

Network affecting: No

PCR: 01229

Module: SWI

Network affecting: No

PCR: 01232

Module: SWI

Network affecting: No