beautypg.com

Features in 86222-09 – Allied Telesis 86222-10 User Manual

Page 2

background image

2

Patch Release Note

Patch 86222-10 for Software Release 2.2.2

C613-10319-00 REV J

Some switch chip register settings have been optimised to improve the
provision of CoS with the newer revision of switching silicon.

Features in 86222-09

Patch file details for Patch 86222-09 are listed in Table 2.

Patch 86222-09 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancements:

A new feature, STP forwarding, has been added. STP forwarding can be
enabled and disabled using the commands:

ENABLE SWI STPFORWARD

DISABLE SWI STPFORWARD

When STP forwarding is enabled, all STP forwarding is ignored and all
BDPUs received on a port are forwarded on all other ports.

The switch now delays sending link traps immediately after a restart to give
the link to the trap host time to come up. A similar change has been made
for the cold start trap. After a 10s delay, all interfaces which are UP have a
link trap generated for them. After that, link traps are sent as normal.

Processing invalid UDP packets caused a memory leak. This issue has been
resolved. Additional debugging facilities were added.

The default setting for the switch port parameter INFILTERING is now OFF,
as specified in IEEE802.1Q. A VLAN will still reject these packets if they are
not from valid VLAN member ports.

The IGMP snooping forwarding process now correctly selects outgoing
ports when DVMRP is managing the multicast routing information.

PCR: 01264

Module: SWI

Network affecting: No

Table 2: Patch file details for Patch 86222-09.

Base Software Release File

86s-222.rez

Patch Release Date

27-Nov-2001

Compressed Patch File Name

86222-09.paz

Compressed Patch File Size

295444 bytes

PCR: 01189

Module: STP, SWI

Network affecting: Yes

PCR: 01242

Module: CORE, SNMP

Network affecting: No

PCR: 01244

Module: SWI, CORE, IPG

Network affecting: No

PCR: 01246

Module: SWI

Network affecting: No

PCR: 01247

Module: IPG

Network affecting: No