Hp 460 w cs gold power supply (92% efficiency) – HP ProLiant DL385p Gen8 Server User Manual
Page 117

Specifications 117
•
HP 460 W CS Platinum Plus power supply (94% efficiency) (on page
•
HP 750 W CS Gold power supply (92% efficiency) (on page
•
HP 750 W CS Platinum Plus power supply (94% efficiency) (on page
•
HP 750 W 48V CS DC power supply (94% efficiency) (on page
•
HP 1200 W CS Platinum Plus power supply (90% efficiency) (on page
For detailed power supply specifications, see the quickspecs on the HP website
HP 460 W CS Gold power supply (92% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
100V to 240V AC
Rated input frequency
50 Hz or 60 Hz
Rated input current
5.5A to 2.2A
Rated input power
526 W at 100 V AC input
505 W at 200 V AC input
Btus per hour
1794 at 100 V AC input
1725 at 200 V AC input
Power supply output
—
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
HP 460 W CS Platinum Plus power supply (94% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
100V to 240V AC
Rated input frequency
50 Hz or 60 Hz
Rated input current
5.2A to 2.1A
Rated input power
509 W at 115 V AC input
495 W at 230 V AC input
Btus per hour
1764 at 100 V AC
1694 at 200 V AC
Power supply output
—
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input