Table 20 port error summary description, 20 port error summary description – HP StorageWorks 2.128 SAN Director Switch User Manual
Page 134

134 Working with diagnostic features
The following example shows output from the
portErrShow
command:
The
portErrShow
command output provides one output line per port. See
for a description of
the error types.
switch:admin> porterrshow
frames enc crc too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
sig=====================================================================
0: 22 24 0 0 0 0 0 1.5m 0 7 3 0 0 0
1: 22 24 0 0 0 0 0 1.2m 0 7 3 0 0 0
2: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4: 149m 99m 0 0 0 0 0 448 0 7 6 0 0 0
5: 149m 99m 0 0 0 0 0 395 0 7 6 0 0 0
6: 147m 99m 0 0 0 0 0 706 0 7 6 0 0 0
7: 150m 99m 0 0 0 0 0 160 0 7 5 0 0 0
8: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
12: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
15: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
32: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
33: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
34: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
35: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
36: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
37: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
38: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
39: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
40: 99m 146m 0 0 0 0 0 666 0 6 796 7 0 0
41: 99m 149m 0 0 0 0 0 15k 0 2 303 4 0 0
42: 99m 152m 0 0 0 0 0 665 0 2 221 5 0 0
43: 99m 147m 0 0 0 0 0 16k 0 2 144 4 0 0
44: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
45: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
46: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
47: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Table 20
Port error summary description
Error type
Description
frames tx
Frames transmitted
frames rx
Frames received
enc in
Encoding errors inside frames
crc err
Frames with cyclic redundancy check (CRC) errors
too shrt
Frames shorter than minimum
too long
Frames longer than maximum
bad eof
Frames with bad end-of-frame delimiters
enc out
Encoding error outside of frames
disc c3
Class 3 frames discarded
link fail
Link failures (LF1 or LF2 states)
loss sync
Loss of synchronization
loss sig
Loss of signal