Array Diagnostic Utility
The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage
controllers and disk drives. This report provides vital information to assist in identifying faults or conditions
that may require attention. ADU can be accessed from the SmartStart CD ("
) or downloaded from the HP website
Manual ROMPaq disaster recovery
1.
Create a ROMPaq diskette. For more information, see the HP website
(
2.
Power down the server (on page
3.
Insert the ROMPaq diskette.
4.
Set S1, S4, S5, and S6 of the system maintenance switch to On.
5.
Power up the server (on page
o
If the diskette is valid, the server generates two short beeps to indicate that the server is in
disaster recovery mode.
o
If the diskette is invalid or not inserted, the server continues to beep.
6.
Wait while the ROMPaq diskette flashes the system ROM image:
o
If successful, the server generates two short beeps.
o
If unsuccessful, the server generates a sequence of descending audible beeps. Repeat the
disaster recovery process.
7.
Power down the server (on page
8.
Remove the ROMPaq diskette.
9.
Set S1, S4, S5, and S6 of the system maintenance switch to Off.
10.
Power up the server (on page
Keeping the system current
Drivers
The server includes new hardware that may not have driver support on all operating system installation
media.
If you are installing a SmartStart-supported operating system, use the SmartStart software (on page
and its Assisted Path feature to install the operating system and latest driver support.