beautypg.com

HP OmniBook 800 Notebook PC User Manual

Page 10

background image

1-10

Connecting Several SCSI Devices

Because the CD-ROM drive is a SCSI device, it is possible to connect it to your
OmniBook in series with other SCSI devices—this is called a “daisy chain”
connection. Follow these guidelines for connecting your CD-ROM drive with other
SCSI devices:

The CD-ROM drive must be the last device in the daisy chain (the furthest from
the OmniBook).

The CD-ROM drive terminator DIP switch (switch 4) must be set to ON.

Each device in the daisy chain must have a unique SCSI ID number that is not
zero.

All SCSI cables must use shielded cable with the proper connector ends. The
cable should be shorter than 5 feet (1.5 meters).

The SCSI terminator and ID number DIP switches are located on the bottom of the
CD-ROM drive. Each switch is numbered: 1 through 3 are the ID number switches,
and 4 is the terminator switch.

The table below shows how to set the ID switches for different SCSI ID numbers.

SCSI ID

ID Switch Number

Number

1

2

3

0

off

off

off

1

on

off

off

2

off

on

off

3

on

on

off

4

off

off

on

5

on

off

on

6

off

on

on

DIP Switches