beautypg.com

Hp rom-based setup utility, Using rbsu, Hp rom-based setup – HP ProLiant BL490c G6 Server-Blade User Manual

Page 49: Utility

background image

Configuration and utilities 49

SmartStart assists the deployment process by performing a wide range of configuration activities, including:

Preparing the system for installing "off-the-shelf" versions of leading operating system software

Installing optimized server drivers, management agents, and utilities automatically with every assisted
installation

Testing server hardware using the Insight Diagnostics Utility ("

HP Insight Diagnostics

" on page

55

)

Installing software drivers directly from the CD. With systems that have Internet connection, the
SmartStart Autorun Menu provides access to a complete list of ProLiant system software.

Enabling access to the Array Configuration Utility (on page

51

) and Erase Utility (on page

54

)

SmartStart is included in the HP Insight Foundation suite for ProLiant. For more information about SmartStart

software, see the HP Insight Foundation suite for ProLiant or the HP website

(

http://www.hp.com/go/foundation

).

HP ROM-Based Setup Utility

RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration

activities that can include the following:

Configuring system devices and installed options

Enabling and disabling system features

Displaying system information

Selecting the primary boot controller

Configuring memory options

Language selection

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or

the HP website (

http://www.hp.com/support/smartstart/documentation

).

Using RBSU

To use RBSU, use the following keys:

To access RBSU, press the F9 key during power-up when prompted.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

To access Help for a highlighted configuration option, press the F1 key.

IMPORTANT:

RBSU automatically saves settings when you press the Enter key. The utility does

not prompt you for confirmation of settings before you exit the utility. To change a selected setting,
you must select a different setting and press the Enter key.

Default configuration settings are applied to the server at one of the following times:

Upon the first system power-up

After defaults have been restored

Default configuration settings are sufficient for proper typical server operation, but configuration settings can
be modified using RBSU. The system will prompt you for access to RBSU with each power-up.