Example of viewing tns header information – HP Integrity NonStop H-Series User Manual
Page 30
Viewing TNS or TNS/E Region Information
TNSVU User’s Guide— 528143-003
4 -9
Example of Viewing TNS Header Information
Example of Viewing TNS Header Information
•
The following example displays TNS header information for the calls4x file.
calls4x> tnsheader
TNS OBJECT CODE FILE HEADER
*: use values from Code Space Information List
*Byte addr of code area: 0x800; wd length: 0x0
Byte addr of data area: 0x1800; wd length: 0x800
*Byte addr of External Proc Ident List: 0x2800; wd length: 0x2a
*Byte addr of External Proc Fixup List: 0x2854; wd length: 0x5
Byte addr of Internal Proc Ident List: 0x285e; wd length: 0x4f
Byte addr of Internal Proc Fixup List: 0x28fc; wd length: 0x8
Byte addr Global Code Str Fixup List: 0x290c; wd length: 0x0
Byte addr Global Code Word fixup list: 0x290c; wd length: 0x0
Byte Addr of first ESIL structure: 0x0; wd length (total): 0x0
Byte Addr of first CSIL structure: 0x290c; wd length (total): 0x2c
Byte Addr of Run-Time Data Unit List: 0x0; wd length: 0x0
Byte addr of Inspect region: 0x3000; wd length: 0x14ac
Byte addr of Binder region: 0x4600; wd length: 0xfdc
Byte addr of MIPS region: 0x0; byte length: 0x0
Byte addr of IPF region: 0x5800; byte length: 0x3094
Byte addr of IPIL entry for MAIN: 0x287a
*PEP table size: 011
Initial P value: 0157
*Num nonpriv: 7
*Num callable: 0
*Num priv: 0
*Wd size of resident code: 0x1
Initial L value: 0x2
Num data pages required for execution: 64
*Wd length of global read-only data: 0x0
Object file version: 0
Data bitmap (octal): 100000 0 100000
CPU version required (octal): 177777
Language mask (octal): 100200
Code Seg that has MAIN proc: 0