beautypg.com

Hot-plug hard drive options, Removing a hot-plug sas or sata hard drive – HP ProLiant DL560 Gen8 Server User Manual

Page 45

background image

Hardware options installation 45

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

3.

Extend the server from the rack (on page

18

).

4.

Remove the access panel (on page

20

).

5.

Remove the air baffle (on page

23

).

6.

Open the DIMM slot latches..

7.

Install the DIMM.

8.

Install the air baffle (on page

24

).

9.

Install the access panel (on page

20

).

10.

Install the server into the rack ("

Installing the server into the rack

" on page

30

).

11.

Connect each power cord to the server.

12.

Connect each power cord to the power source.

13.

Power up the server (on page

18

).

Use RBSU ("

HP ROM-Based Setup Utility

" on page

74

) to configure the memory mode.

For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED

combinations (on page

8

)."

Hot-plug hard drive options

When adding hard drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

If only one hard drive is used, install it in the bay with the lowest device number.

Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.

Removing a hot-plug SAS or SATA hard drive