HP ProLiant DL145 G3 Server User Manual
Page 38

Troubleshooting 38
Fan problems
General fan problems are occurring
Action:
1.
Be sure the fans are properly seated and working.
a.
Follow the procedures and warnings in the server documentation for removing the access panels
and accessing and replacing fans.
b.
Unseat, and then reseat, each fan according to the proper procedures.
c.
Replace the access panels, and then attempt to restart the server.
2.
Be sure the fan configuration meets the functional requirements of the server. Refer to the server
documentation.
3.
Be sure no ventilation problems exist. If you have been operating the server for an extended period
of time with the access panel removed, airflow may have been impeded, causing thermal damage
to components. Refer to the server documentation for further requirements.
4.
Be sure no POST error messages are displayed while booting the server that indicate temperature
violation or fan failure information. Refer to the server documentation for the temperature
requirements for the server.
5.
Replace any required non-functioning fans and restart the server. Refer to the server documentation
for specifications on fan requirements.
6.
Be sure all fan slots have fans or blanks installed. Refer to the server documentation for requirements.
7.
Verify the fan airflow path is not blocked by cables or other material.
Hard drive problems
System completes POST but hard drive fails
Action:
1.
Be sure no loose connections (on page
2.
Be sure no device conflict exists.
3.
Be sure the hard drive is properly cabled and terminated if necessary.
4.
Be sure the SCSI cable is working by replacing it with a known functional cable.
5.
Run Insight Diagnostics ("
" on page
) and replace failed components as
indicated.
Hard drive is not recognized by the server
Action:
1.
Check the LEDs on the hard drive to be sure they indicate normal function. Refer to the server
documentation or the HP website for information on hard drive LEDs.
2.
Be sure no loose connections (on page
3.
Remove the hard drive and be sure the configuration jumpers are set properly.
4.
If using an array controller, be sure the hard drive is configured in an array. Run the array
configuration utility.
5.
Be sure the drive is properly configured. Refer to the drive documentation to determine the proper
configuration.
- ProLiant DL160 G6 Server ProLiant DL185 G5 Server ProLiant DL180 G5 Server ProLiant DL160 G5 Server ProLiant DL180 G6 Server ProLiant DL160se G6 Server ProLiant DL170h G6 Server ProLiant DL165 G5p Server ProLiant DL165 G6 Server ProLiant DL160 G5p Server ProLiant DL140 G3 Server ProLiant DL145 G2 Server ProLiant DL180 Server ProLiant DL140 G2 Server ProLiant DL165 G7 Server ProLiant DL165 G5 Server