Plumbing Schematic–Flow Exceeding 70-GPM
Plumbing Requirements (continued)
INSTALLATION
Plumbing Schematics – Flow 30 to 70-GPM
Bypass Check Valve
AquaCal P.N.: 2556
-or equal to-
Del Ind. PN: CO-0103
T
YPICAL
P
OOL
- F
LOW
G
REATER THAN
70-
GPM
(2-HP P
UMP OR
L
ARGER
)
T
YPICAL
P
OOL
- F
LOW LESS THAN
70-
GPM
P
OOL
/S
PILL
O
VER
S
PA
- T
WO
P
UMP
S
YSTEM
H
EAT
P
UMP WITH
S
OLAR
P
ANELS
P
OOL
/S
PILL
O
VER
S
PA
- O
NE
P
UMP
S
YSTEM
Water flow exceeding 70-GPM may damage titanium condenser; such damage will NOT be
covered under the equipment warranty. Install a bypass check valve (AquaCal P.N.: 2556, or
equal to Del Industries P.N.: CO-0103) whenever water flow rate may exceed 70-GPM. Contact
AquaCal Technical Support (800-786-7751) for guidance regarding testing for water flow rate.
Failure to heed the following may result in damage to
equipment.
CAUTION !