beautypg.com

Appendix a - functional description, Doubler block diagram, A - f – ADC and 3 Doubler User Manual

Page 31: Ppendix, Unctional, Escription

background image

LTPH-UM-1234-01

Appendix A - Functional Description

HDU-409 Lists 1, 2, and 3

April 30, 2003

25

A

PPENDIX

A - F

UNCTIONAL

D

ESCRIPTION

HiGain uses the ADC Two-Binary, One-Quaternary (2B1Q) HDSL
transceiver system to establish two full-duplex 784 kbps data channels
between the HLU, HDU, and HRU units. Each HDU-409 increases the
maximum range by approximately 12,000 feet (3.7 km) using 24 AWG or
9,000 feet (2.75 km) using 26 AWG per doubler. See Table 2 on page 3 for
deployment rules.

A block diagram of the HDU-409 with pinouts is shown in

Figure 7 on

page 25

. The doubler unit power supply uses the HDSL simplified line

voltage to produce +5 Vdc and +3 Vdc required by the HDU-409 electronics.
The power feed is passed on to the HDSL output pair to power a second
doubler or a remote unit.

The typical power dissipation of the doubler unit is 3W.

Figure 7.

Doubler Block Diagram

Power

Supply

and

GFD

3 Ring

4 Tip

HDSL 1

OUT

11 Ring

12

Tip

Tip 6

Tip 9

Ring 5

Ring 8

HDSL 1 IN

HDSL 2 IN

HDSL 2 OUT

80 to 200 V

-

+

+3 V

+5 V

475 K

Output
Span
Voltage
Control

Microprocessor

Status

Loop 1

CO

Field

Loop 2

1

10

Frame

Ground

HDSL

IN

XCVRS

HDSL

OUT

XCVRS

H0083-A

This manual is related to the following products: