FPC-8057 User’s Manual

2.2.3 CE Requirements

To make a FPC-8057 comply with EMC directives, and to reduce

susceptibility to electrical interference, a separate #14 AWG ground wire

should be taken to the chassis ground terminal of the power connector. This

ground connection should be run directly to the central star earth

connection point (as recommended in most Installation Instructions).

2.2.4 Safety Guidelines

This section presents recommended installation practices, and

procedures. Since no two applications are identical, these

recommendations should be considered as guidelines.

Hardware Considerations WARNING!

The system designer should be aware that devices in Controller systems

could fail and thereby create an unsafe condition. Furthermore, electrical

interference in an operator interface, such as a FPC-8057 can lead to

equipment start-up, which could result in property damage and/or physical

injury to the equipment operator.

If you, or your company, use any programmable control systems that

require an operator or attendant, you should be aware that this potential

safety hazard exists and take appropriate precautions. Although the specific

design steps depend on your particular application, the following

precautions generally apply to installation of solid-state programmable

control devices. In addition, these precautions conform to the guidelines for

installation of Controllers as recommended in the NEMA ICS 3-304 Control

Standards.

12

Installation Instructions