FPC-8057 User’s Manual

FUSE Replacement:

The fuse use on FPC-8057 is:

BUSSMANN

Fast Acting, Glass Tube

Rating: 250VAC, 1A Size:

5x20mm

Warning:

Make sure the power off before replace the fuse. Do

not replace the fuse with a different rating fuse.

1.

2.

2.2.2 Grounding

Requirements

Chassis ground must be used. DC ground is not directly coupled to Earth

ground internally. It is preferable not to ground DC negative return to

chassis ground as poor site earths can introduce noise into a system, but if

necessary an earth connection should be made, from the power supply

return point to the central star earth point. Ground conductors should be as

short and as large in size as possible. The conductors must always be

large enough to carry the maximum short circuit current of the path being

considered. Ground conductors should be connected to a tree from a

central star earth ground point. This ensures that no ground conductor

carries current from any other branch.

11

Installation Instructions