Set id, Communication parameters, Rs-232c configurations – LG 26LC7D User Manual
Page 93: Appendix

91
APPENDIX
Press the
M
ME
EN
NU
U
button and then use
D
D
or
E
E
button
to select the S
SE
ET
TU
UP
P menu.
Press the
G
G
button and then use
D
D
or
E
E
button to
select S
Se
ett IID
D.
Press the
G
G
button and then use
D
D
or
E
E
button to
adjust S
Se
ett IID
D to choose the desired TV ID number.
The adjustment range of Set ID is 1~99.
Press
E
EX
XIIT
T
button to return to normal TV viewing.
Use this function to specify a TV ID number.
Refer to ‘Real Data Mapping1’. See page 93.
SET ID
Communication Parameters
■
Baud rate : 9600 bps (UART)
■
Data length : 8 bits
■
Parity : None
■
Stop bit : 1 bit
■
Communication code : ASCII code
■
Use a crossed (null modem) cable.
RS-232C Configurations
Auto programme
Manual programme
Programme edit
Signal strength
Set ID
G
1
Auto programme
Manual programme
Programme edit
Signal strength
Set ID
2
1
3
4
PC
TV
RXD
2
3
TXD
TXD
3
2
RXD
GND
5
5
GND
DTR
4
6
DSR
DSR
6
4
DTR
RTS
7
8
CTS
CTS
8
7
RTS
D-Sub 9
D-Sub 9
PC
TV
RXD
2
3
TXD
TXD
3
2
RXD
GND
5
5
GND
DTR
4
6
DTR
DSR
6
4
DSR
RTS
7
7
RTS
CTS
8
8
CTS
D-Sub 9
D-Sub 9
7-Wire Configurations (Standard RS-232C cable)
3-Wire Configurations(Not standard)
2
3
1