Port Diagnostic Test
The Port Diagnostic Test checks all ports. If a problem is detected, an LED in
the corresponding row (which indicates the malfunctioning port) and column
(which indicates the failed component) will light up as shown below.
LED Indicator
(Column)
Color
Diagnostic Test Status
4 (20%)
Green
Failed Port IC Test
5 (35%)
Green
Failed Routing Table Test
6 (50%)
Orange
Failed Input Queue RAM Test
7 (70%)
Orange
Failed Output Queue RAM Test
Note:
Enabling the Diagnostic function activates tests similar to the one performed upon
power on. After successfully completing diagnostics, the system returns to normal
operation.
Port Status Display
Port 1
Port 2
Status
Link
Status (Link) -
Indicates a valid network connection associated with the port.
LED Activity
Condition
Indication
STEADY LIGHT
ON
Indicates a valid link has been established on this port.
NO LIGHT
OFF
No valid link has been established on this port.
Troubleshooting
:
If the Link LED does not light up when a device is connected to its corre-
sponding port, check that both the hub and connected device are powered on. For devices
connected to the hub using twisted-pair cable, check that the cable length does not exceed
100 meters. You should have standard, straight-through cables and not crossover or other
specialized cables.