36
C. Display is reading “Rotation Sensor Fail.”
1. Magnet and rotation read switch are out of adjustment.
2. Trunnion shaft has moved forward.
3. Magnet is missing.
4. Rotation read switch is broken.
5. Broken V-belt.
6. Faulty drive motor.
7. Faulty wiring connection between read switch and computer.
8. Faulty drive contactor.
9. Faulty computer (computer is not sensing rotation).
10. Faulty arc suppressor (A.S.) board.
D. Display is reading “NO Airflow.”
1. Blower motor is not coming on.
2. Blower motor is spinning in the wrong direction.
3. Dirty lint screen.
4. Exhaust is clogged and is in need of cleaning.
5. Sail switch damper is hung up.
6. Lint drawer or main door is not sealing.
7. Faulty sail switch (very tough).
8. Faulty wiring connection between sail switch and computer.
9. Faulty blower contactor.
10. Faulty arc suppressor (A.S.) board.
11. Faulty 24 V transformer.
12. Faulty computer board.
- SL2929 (8 pages)
- AD-15 Phase 7 (31 pages)
- ML-75DIII (65 pages)
- AD-236 (33 pages)
- AD-50V (61 pages)
- ML-96HS (38 pages)
- 75 lb (6 pages)
- SL2020 (8 pages)
- AD-758DV (52 pages)
- Aquatex AD-76 (36 pages)
- MDG-75 (66 pages)
- MLG-130DR (HSI) (45 pages)
- MLG31PCB (44 pages)
- AD-410 (72 pages)
- AD-75THS (49 pages)
- Direct Spark Ignition ADG-530DSi II (33 pages)
- MLG32PD3 (39 pages)
- ML-55 (52 pages)
- ML-96 (34 pages)
- ADG-410 (75 pages)
- ADG-320D (53 pages)
- Phase 7 Gas/Steam AD-464 (62 pages)
- AD-120ES (50 pages)
- Gas/Electric/Steam ML-55HS (56 pages)
- AD-840 (47 pages)
- MDG31 (26 pages)
- D20 (37 pages)
- Aquatex AD-52 (37 pages)
- Phase 7 D30 (39 pages)
- 30 lb. Stacked Models (26 pages)
- ADH-120 (46 pages)
- ML-96D (43 pages)
- Super AD-50 (54 pages)
- ML-122 (52 pages)
- SL31 (12 pages)
- Super AD-30 (63 pages)
- MDG30V (52 pages)
- AD-670 (60 pages)
- SL31AD-15 (72 pages)
- ADS-464 II (80 pages)
- ML-190 (42 pages)
- Heat Reclaimer AD-170HR (20 pages)
- 50 lb. Single Pocket MDG50V (52 pages)
- 24 VAC Phase 5 AD-330 (40 pages)
- D75 (42 pages)