M. HI-LIMIT (Gas Models ONLY)

A hi-limit thermostat is located at the burner. This is a manual
reset disc-type thermostat set at 330º F (166º C). If the flame in
the burner should get too hot, this thermostat will shut off the burner.
This is generally caused by low airflow through the dryer.

N. AUTOMATIC RESET THERMOSTAT

This is located inside the dryer in the lint compartment
above the lint drawer. This thermostat senses the
heated air after it has passed through the tumbler
(basket). If the air temperature gets too hot, the
thermostat will shut off the burner. The dryer will not
run until the air temperature cools down. At this time,
the thermostat will reset. Tumbler (basket) and blower
will run, but the dryer will not heat.

O. LINT DRAWER

The lint drawer is a pullout type and is located at
the bottom of the dryer in the lint compartment.
Simply grab the lint drawer handle, slide out the
drawer, brush off the lint, and slide the drawer back
in. The lint screen must be kept clean in order for
the dryer to operate properly and efficiently.