PROGRAMMING MODE continued
In Service Display
Time & Day
Regen Time & Day
Salt Amount
SU MO TU WE TH FR SA DAYS
Capacity
Time & Day
Regen Time & Day
Salt Amount
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Hardness
Figure 6
The display shows the number of the tank in service (small
digit next to CPH position). The display also alternates
between Capacity Remaining and Flow Rate (faucet icon) for
the tank in service.
NOTE: The Regen icon is only on when in regeneration.
NOTE: The faucet icon is displayed on all the 9100 TS
controls when there is flow. The 9100 TS will show
the faucet icon when the flow rate is displayed,
even if the flow rate is zero. The faucet icon will
turn off when the capacity is displayed. In service
flow rate display can be replaced with a clock
display using Level II Programming (Parameter
P10).
Programming Overview
The 9100 TS control includes multiple program levels that
allow water treatment professionals to customize the system
for many water conditions. Additionally, historical data can be
viewed allowing quick and easy troubleshooting. In most cases
Level I Programming is all that is required to set up the water
conditioning system for proper operation. A brief description of
each program level is listed below.
Level I - Used to program control for normal applications.
Level II (P-Values) - Allows the installer to customize
programming for non-standard applications.
Level III (C-Values) - Allows the installer to adjust length of
select cycles for non-standard applications.
Level IV History (H-Values) - Allows access to historical
information for troubleshooting the system.
NOTE: If a button is not pushed for thirty seconds, the
control returns to normal operation mode.
Level I Programming
The 9100 TS control can be quickly programmed by following
the sequential procedure in the section "Placing Water
Conditioning System Into Operation". Level I Program
parameters are those that can be accessed by pressing the
UP or DOWN buttons. Step-by-step instructions are shown on
previous page.
• Resin Volume Setting: Set to match the volume (cubic
feet) of resin in the mineral tank.
• Time of Day: Includes PM indicatior. Can be set to display
as a 24-hour clock. See Level II programming.
• Day of Week: Set to actual day of the week.
• Time of Regeneration: Fully adjustable. Default is 2:00 AM.
• Days Override: Range 0.5 to 30 days. Leave at 0 to disable.
• Salt Dosage: Set at pounds of salt per cubic foot of resin
in the conditioner tank.
NOTE: When the control is set up for a twelve-hour clock
a PM indicator will illuminate when the displayed
time is in the PM hours. There is no AM indicator.
Programming the Lockout Feature
All Level I parameters can be locked out when the control is in
Level II Programming. Simply press the REGEN button during
Level II Programming and a lock icon will appear indicating that
the specific setting has been locked out. When locked out, the
setting cannot be adjusted in Level I Programming. To disable
the Lock Out feature, press the REGEN button when in Level
II. The lock icon will not be displayed.
Resin Volume
The amount of resin can be determined by the diameter of the tank.
Tank Diameter
(inches)
Resin Volume
US
Metric
8
0.90
9
1.25
10
1.75
12
2.25
9100 TS Upflow JA11 • 7