Water Inc HOUSEPURE HP01 User Manual
Page 7
Filter Start-Up - Tank Fill and Initial BackWash
Cycle the valve to Cycle 3, Rapid Rinse.
a. Press and Hold the Cycle button for about
5 seconds until the valve activates. The
Valve will stop at Cycle 1 (Backwash)
b. Press the Cycle button to advance to Cycle
3, Rapid Rinse.
a. Slowly open the main water supply valve.
Flush the piping for a few minutes.
b. After flushing the pipes, slowly open the
inlet valve on the bypass valve. Allow the
tank to fill slowly. Continue filling slowly
until a clear, steady stream comes out of
the drain line then close the inlet valve on
the bypass.
a. Press the Cycle button once to return to the
Service position.
b. Let the system stand for 15 to 20 minutes
to allow the media to absorb the water.
18
19
20
Installation Manual Page 5
Put the Bypass Valve in the Bypass Position:
CYCLE button
17
Bypass Valve in
Bypass Position
Inlet Valve
15:00
a
b