4. Troubleshooting-guide



















SIM-card recognized?

SIM-card can be tested by

AT+CPIN?

Answer:

+CPIN: READY

. (Answer

:+CPIN: SIM

PIN

: you should enter PIN first).


Verify the signal-quality

with

AT+CSQ?

. (repeat command a couple of times every 10secs.) It should never

drop below 10, critical connections could work down to about 7. Find best antenna-
location with mobile phone.


Network-attached?

To control that the module is connected to the network, you see the response of

AT+CREG

with the HEX-info about the cell. (First, enable CREG with

AT+CREG=2

)


DTE-baud-rates

Control if on both sides the data-rate of the DTE-DCE connection (of the computer-
terminal) is set higher than 9600 (best is 115200 as default for all applications). The
GSM-module can stay at autobaud (

AT+IPR=0

). For GPRS, set data-rate to 115200

baud.
If your application will work with lower DTE-rates, you can test these settings of

AT+CBST

later, because 9600 is the standard of many modems. (19200/2400/1200

not working always). Set baud-rate on GSM-Module: use

AT+IPR

command.

Regarding hyper-terminal: We made bad experiences with it, sometimes it hangs up
and there is no comfort. We use Procomm 4.8 from Symantec, there you can also write
very comfortable scripts with window-support. Also as a dumb terminal, it is much more
reliable. They have also very good support in one day.

The following steps apply to analog-modems and ISDN-TA's (digital phone-
connection).
Exceptions are marked.

There is never a simple "no connection". There are many causes for
this, which can be excluded step-by-step. If you never had a
successful data-connection, you should test first with an analog
modem at the other side. Also, if possible, avoid problems with local
company-exchanges, using a direct phone-line. This applies specially
if you call to a digital "modem" (ISDN-TA). You can test these
configurations later. It is also helpful, to test different numbers on both
sides. (ISDN/analog, direct/local exchange, mobile phone on called
side. Different providers for GSM-Module.
It is very recommended to make all tests in both directions, because in
many cases of failure, the other direction is working. This helps to find
the error.