Important Safety Instructions

SAVE THESE INSTRUCTIONS FOR

FUTURE REFERENCES

TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING*:
SMOTHER FLAMES with a close-fi tting lid,

cookie sheet, or metal tray, then turn off
the burner. BE CAREFUL TO PREVENT
BURNS. If the fl ames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.

NEVER PICK UP A FLAMING PAN - You may

be burned.

DO NOT USE WATER, including wet dishcloths

or towels - a violent steam explosion will result.

Use an extinguisher ONLY if:
A. You know you have a Class ABC

extinguisher, and you already know how to
operate it.

B.

The

fi re is small and contained in the area

where it started.

C.

The

fi re department is being called.

D.

You

can

fi ght the fi re with your back to an

exit.

* Based on “Kitchen Firesafety Tips” published by

NFPA.

For general ventilating use only. Do not use to

exhaust hazardous or explosive materials and
vapors.

To reduce risk of fi re and to properly exhaust

air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls or ceilings
or into attics, crawl spaces or garages.

This blower assembly is approved for use with

the following Electrolux Telescoping Downdraft
Systems: EI30DD10KSA, EI36DD10KSA,
FH30DD50MSA and FH36DD50MSA only.

Use of this blower assembly with any other
product or in any other confi guration is
hazardous and voids the product warranty.

NOTE

Consult a licensed ventilation contractor or

qualifi ed technician for proper installation of
exhaust ducting.

Locate the cooking area for minimum cross

drafts - away from doors and windows, when
possible.

Ducts must be of adequate size and duct runs

should be as short and straight as possible.
Where turns are necessary, keep turning radius
as large and smooth as possible.

The ducting must be air tight. Use a minimum

of 2 sheet metal screws at every duct joint.
Then, seal the duct joints with a high quality
duct tape.

In duct runs less than 10 equivalent straight

feet, the remote blower may interfere with the
cooktop burner performance due to the high
volume of air moved. An adjustable damper
(not included) should be installed in the
ducting system. The damper can be adjusted
so that proper ventilation and cooktop burner
performance is achieved.

Installation of duct work should be carefully

planned if it is to go under a concrete slab fl oor.
The duct trench should be boxed to prevent
collapse from the wet cement. Be sure to allow