ATTACH THE MOUNTING
PLATE TO THE WALL

B3.

USE TOP CABINET TEMPLATE

FOR PREPARATION OF TOP
CABINET

B4.

Read the instructions on the TOP CABINET
TEMPLATE.

Tape it underneath the top cabinet.

Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.

CAUTION:

Wear safety goggles when drilling holes

in the cabinet bottom.

Wall

Mounting

Plate

Spacing for Toggles More
Than Wall Thickness

Toggle
Bolt

Toggle Wings

To use toggle bolts:

Bolt End

Installation Instructions

You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through.

Attach the plate to the wall using toggle bolts.
At least one wood screw must be used to attach
the plate to a wall stud.

Remove the toggle wings from the bolts.

Insert the bolts into the mounting plate through
the holes designated to go into drywall and reattach
the toggle wings to

3

4

″ (19 mm) onto each bolt.

1

2

Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.

NOTE:

Before tightening toggle bolts and wood

screw, make sure the bottom of the mounting plate
touch the bottom of the cabinet when pushed flush
against the wall and that the plate is properly
centered under the cabinet.
CAUTION:

Be careful to avoid pinching fingers

between the back of the mounting plate and the wall.

Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.

3

4

2

1 Remove and save screw that holds blower motor

to microwave.

ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
BACK EXHAUST

B5.

End B

End A

will extend far enough to allow you to adjust
the blower unit.

Back of
Microwave

Blower Motor

Blower Motor
Screw

Forward

Openings Facing

Carefully pull out the blower unit. The wires

Before: Fan Blade

EN-17