beautypg.com

List of symptoms – Brother XR1300 User Manual

Page 103

background image

101

4

————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————

List of symptoms

Before sewing

Symptom

Possible cause

How to put it right

Reference

The needle

threader can not

be used. (For

models equipped

with the needle

threader lever.)

You have not moved the needle
holder to its highest position.

Raise the needle either by turning the
handwheel toward you
(counterclockwise) so that the mark
on the wheel points up or by pressing

(needle position button) once or

twice.

page 23

The needle is incorrectly installed.

Correctly install the needle.

page 30

The sewing light

does not come on.

The sewing lamp is damaged.

Contact your retailer or the nearest
authorized service center.

The machine is not turned on.

Turn on the machine.

page 12

Bobbin thread

does not wind

neatly on the bob-

bin.

The thread is not passed through the
bobbin-winding thread guide
correctly.

Correctly pass the thread through the
bobbin-winding thread guide.

page 17

Bobbin spins slowly. (for models
equipped with the sewing speed
controller.)

Move the sewing speed controller to
the right (so that the speed will be
fast).

page 19

The thread that was pulled out was
not wound onto the bobbin correctly.
(For models equipped with the fast
bobbin winding system.)

Wind the thread that was pulled off
round the bobbin five or six times
clockwise.

page 18

The thread does

not pass through

the eye of the nee-

dle. (For models

equipped with the

needle threader

lever.)

You have not moved the needle
holder to its highest position.

Raise the needle either by turning the
handwheel toward you
(counterclockwise) so that the mark
on the wheel points up or by pressing

(needle position button) once or

twice.

page 23

The needle is incorrectly installed.

Correctly install the needle.

page 30

The needle

threader lever

does not lower to

the correct

position. (For

models equipped

with the needle

threader lever.)

The needle has not been raised to the
correct position.

Press the needle position button.

page 23

While winding the

bobbin, the

bobbin thread was

wound below the

bobbin winder

seat.

You have not wound the bobbin
thread properly.

After removing the thread wound
below the bobbin winder seat, wind
the bobbin correctly.

page 15

This manual is related to the following products: