• When the unit is used in its extractor version, a sufficiently large

ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.

• National and regional building regulations impose a number of

restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in the
same room.

• Hoods can only be used safely with appliances connected to a

chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approxi-
mately 500-600 cm

2

large to avoid the possibility of a depression

being created during operation of the hood.

• If you have any doubts, contact the relevant controlling authority or

building inspector’s office.

• Since the rule for rooms with fuel burning appliances is “outlet hole

of the same size as the ventilation hole”, a hole of 500-600 cm

2

,

which is to say a larger hole, could reduce the performance of the
extractor hood.

• If the hood is used in its filtering function, it will operate simply and

safely in the above conditions without the need for any of the
aforementioned measures.

• When the hood is used in its extractor function, the following rules

must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
always follow a gentle curve only
— keep the hose as large as possible (preferably the same
diameter as the outlet hole).

• Failure to observe these basic rules will drastically reduce the

performance and increase the noise levels of the extractor hood.