background image

ADSP-2186

REV. 0

–26–

TIMING PARAMETERS

Parameter

Min

Max

Unit

IDMA Read, Long Read Cycle

Timing Requirements:
t

IKR

IACK Low before Start of Read

1

0

ns

t

IRP

Duration of Read

1

15

ns

Switching Characteristics:
t

IKHR

IACK High after Start of Read

1

15

ns

t

IKDS

IAD15–0 Data Setup before

IACK Low

0.5 t

CK

– 10

ns

t

IKDH

IAD15–0 Data Hold after End of Read

2

0

ns

t

IKDD

IAD15–0 Data Disabled after End of Read

2

10

ns

t

IRDE

IAD15–0 Previous Data Enabled after Start of Read

0

ns

t

IRDV

IAD15–0 Previous Data Valid after Start of Read

15

ns

t

IRDH1

IAD15–0 Previous Data Hold after Start of Read (DM/PM1)

3

2 t

CK

– 5

ns

t

IRDH2

IAD15–0 Previous Data Hold after Start of Read (PM2)

4

t

CK

– 5

ns

NOTES

1

Start of Read =

IS Low and IRD Low.

2

End of Read =

IS High or IRD High.

3

DM read or first half of PM read.

4

Second half of PM read.

t

IRP

t

IKR

PREVIOUS

DATA

READ
DATA

t

IKHR

t

IKDS

t

IRDV

t

IRDH

t

IKDD

t

IRDE

t

IKDH

IAD 15–0

IACK

IS

IRD

Figure 23. IDMA Read, Long Read Cycle