Adsp-2186, Timing parameters – Analog Devices ADSP-2186 User Manual

Page 18

background image

ADSP-2186

REV. 0

–18–

TIMING PARAMETERS

Parameter

Min

Max

Unit

Interrupts and Flag

Timing Requirements:
t

IFS

IRQx, FI, or PFx Setup before CLKOUT Low

1, 2, 3, 4

0.25 t

CK

+ 15

ns

t

IFH

IRQx, FI, or PFx Hold after CLKOUT High

1, 2, 3, 4

0.25 t

CK

ns

Switching Characteristics:
t

FOH

Flag Output Hold after CLKOUT Low

5

0.25 t

CK

– 7

ns

t

FOD

Flag Output Delay from CLKOUT Low

5

0.5 t

CK

+ 5

ns

NOTES

1

If

IRQx and FI inputs meet t

IFS

and t

IFH

setup/hold requirements, they will be recognized during the current clock cycle; otherwise the signals will be recognized on

the following cycle. (Refer to “Interrupt Controller Operation” in the Program Control chapter of the ADSP-2100 Family User’s Manual for further information on
interrupt servicing.)

2

Edge-sensitive interrupts require pulse widths greater than 10 ns; level-sensitive interrupts must be held low until serviced.

3

IRQx = IRQ0, IRQ1, IRQ2, IRQL0, IRQL1, IRQE.

4

PFx = PF0, PF1, PF2, PF3, PF4, PF5, PF6, PF7.

5

Flag outputs = PFx, FL0, FL1, FL2, Flag_out4.

t

FOD

t

FOH

t

IFH

t

IFS

CLKOUT

FLAG

OUTPUTS

IRQ

x

FI

PFx

Figure 15. Interrupts and Flags