Parking Lights Flash Rate (Normal Operation)

Flashes

Description

1

x Doors locked, Starter Kill armed.
x End of Run Time.
x

TRUNK

button pressed

x

START

signal received by the Module.

x Cold Weather Mode cancelled.
x Cannot start after maximum number of attempts is reached.

2

x Run Time cancelled.
x Remote start attempt cancelled by remote.

x

Doors unlocked, Starter Kill disarmed.

3

x Entering Cold Weather Mode

4

x +12 volts detected on the Brake line; cranking cancelled
x Entering Tach Learning

5

x New Transmitter learnt
x Tach learnt

6

x Remote start attempt was made with a Tach or a vacuum signal detected

before cranking

8

x Unit reset: occurs when the unit is reset to factory defaults

10

x The Hood Switch line went to ground during cranking or run time

1 – pause –

2

x There was an attempt to start the vehicle while the Module was in Valet

Mode.

2 – pause –

2

x There was an attempt to start the vehicle while the Module was in Home

Valet Mode.

ON solid

x Cold Weather Mode: the Brake Pedal is being held down

ON 2 sec.

x The Hood is up and the Hood Switch line went to ground. This is step one

of the Programming Mode

ON 3 sec.

x First press of the

START

button under Safe Start.

x Entering Home Valet Mode

ON 4 sec.

x

LOCK

or

UNLOCK

pulse (if door pulse is configured to 4 sec.)

ON 25 sec.

x If the Hood Pin-switch has been pressed twice: the Unit went into step 1

of the Programming cycle and no Transmitter activity was detected for 20
seconds

x Or the Unit went into step 1 of the Transmitter Code Learning procedure

and no activity was detected for a few seconds. The Unit has exited the
Transmitter Code Learning procedure.

Irregular

x If the Module gives irregular flashes (1 to 10 flashes followed by a pause,

followed by more flashes), it is in Playback Mode. This occurs when the
Hood-switch line is flashed 3 times.

Constant

flashes

up to 30 sec.

x Panic Mode set off.

P. 11

User Guide

AS-6205 SH