beautypg.com

Amplifier enable (watchdog) relay output – Trio Motion Technology MC403 User Manual

Page 5

background image

An internal relay is used to enable external amplifi ers when the
controller has powered up correctly and the system and application
software are ready. The amplifi er enable is a single pole solid state
relay with a normally open “contact”. The enable relay contact will
be open circuit if there is no power on the controller OR a following
error exists on a servo axis OR the user program sets it open with
the WDOG=OFF command.

ALL STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED WHEN
THE AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT

AMPLIFIER

ENABLE

(WATCHDOG)

RELAY OUTPUT

MC 403

Amplifi er

Enable 1

Amplifi er

Enable 2

V+

V-

Trio Controller

Servo Amplifi er

To other axis enables

24V 0V

0V

Enable

VIN +

VIN-