150 series electric strike, Installation instructions

background image

IMPORTANT NOTE: Ensure any rebate strips or door stops are fi tted before proceeding.

For double-leaf doors, the inactive leaf must be securely fi xed in the closed position and a rebate strip fi tted to prevent
door over-travel.
Strike is suitable for 15mm latches, based on a 3mm door gap.

INSTALLATION INSTRUCTIONS

150 SERIES ELECTRIC STRIKE

Position strike on door jamb in line with the centre of the latch to establish the vertical alignment (see Fig. 1). Ensure that any auxiliary
bolt on the door does not enter the “keeper area” where the latch is positioned when the door is closed.

Ensure that there is no mechanical interference with the strike when door is in the closed position. A minimum of 4mm door gap will
provide a working gap of 1mm. If a working gap of 1mm is not available, rebate the strike into the door frame to give the recommended
clearance (see Fig. 2).

Drill the door frame to provide a cable exit from the strike and connect to control device.

Using strike body as template, drill and fi t the 3 fi xing screws to complete installation (see Fig. 3).

1.

2.

3.

4.

Page 1

DRAWINGS NOT TO SCALE. INFORMATION IN THIS DATASHEET MAY BE CHANGED WITHOUT NOTICE.

An ASSA ABLOY Group brand

Fig. 3 - Mount Strike on Door Jamb by Fitting Fixing Screws

*These dimensions have a tolerance of +0.8mm/-0

Fig. 1 - Position Strike on Door Jamb, In Line with Latch

Fig. 2 - Ensure 1mm Working Gap without Mechanical Interference

Keeper Area

Recommended 4mm gap

Minimum 1mm working gap

Latch

Strike

33

32

4

Front Face of Lock Latch

Back Edge

35

70

9

35

59