4.2 Examples of communications to be written
Example: Request message: This requests this product set at address 03 to set "the A1F setting to
(High-level computer)
135" (write 135).
(Set the event 1 function to the following: Error alarm type to be PV
error alarm 1, alarm type to be deviation lower limit alarm 3 and
additional function to be alarm hold + standby sequence (5).)
In response to that,
Response message: This returns a notice that the request message has been received.
(This product)
*Check that it has been written by reading the data separately.
Write request message (transmitted from a high-level computer)
0
A
F
0
S
T
X
3
A
C
K
B
C
C
E
T
X
①
②
⑥
⑦
⑧
S
T
X
3
W
B
C
C
1
E
T
X
①
②
③
④
⑥
⑦
0
0
0
1
1
⑤
Code
Code, data
ASCII code, note 2)
① Start code
STX
02H
② Address
03
32H 33H
③ Request contents
W (Write)
57H
④ Identifier, note 1)
A2F
41H 33H 46H
⑤ Numerical data
00135
30H 30H 31H 33H 35H
⑥ End code
ETX
03H
⑦ BCC data request
56H
response
04H
⑧ Acknowledge code
ACK
06H
Note 1): See "7. Table of identifiers (codes)."
Note 2): For the ASCII codes, see "8. Table of ASCII codes."